2010 Call Volume
  Fire EMS
January  8  
February  18  
March  9  
April  12  
May  10  
June  7  2
July  12  1
August  19  1
September  2  
October    
November    
December    
Total 974

View Call Volume History

Contact Information

Kidder Twp. Volunteer Fire Company No. 1
RR1 Box 82-F
White Haven, PA  18661

Non-Emergency:
570-443-2344

Emergency:
911

Contact Us

Links

Fearnots Volunteer Fire Company, Foster Township

Luzerne County Station 134


Gilbertsville Fire/Rescue


Nesquehoning Hose Co. # 1

Carbon County FD 13, Sta. 1




 Fire Glossary
 Print this page

Search:

Click a letter to view all entries that begin with that letter:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Page: | 1 | 2 |

Palmer drought severity index (PDI)
Technique for measuring impact of soil moisture changes on vegetation, for predicting fire danger and fire behavior.


Panic doors, panic hardware
Fire safety appliance permitting locked doors (typically self-closing) to be opened from the inside when pressed with sufficient force, thus permitting a person to open the door without having to turn a knob or lever.


Parallel attack
Fire containment method where crews constructs fireline at some distance from the edge of the fire (e.g., 100 yards) and then burn out the fuel in the buffer as the fireline is completed.


PASS device, personal alert safety system
An alarm device which signals that a firefighter is in trouble. It can be activated manually by the firefighter, or activates automatically if the firefighter stops moving. May be integral to SCBA or separately activated.


Passport (accountability)
System in which each firefighter has an identification document that is collected by the person in charge of accounting for the current location of the respective individuals, and returned to the firefighter when he or she leaves the dangerous area.


Perennial grasses
An extremely volatile fuel, after curing, in May, June, July, which can lead to large, fast fires that may reach larger fuels.


Personal alert safety system
See PASS device in Glossary of firefighting equipment.


Personnel accountability report
End-result of personnel accountability system. Best report is all hands, AOK worst is squad missing.


Personnel accountability system
Tag, 'passport', or other system for identification and tracking of personnel at an incident, especially those entering and leaving an IDLH area; intended to permit rapid determination of who may be at risk or lost during sudden changes at the scene.


Pickheaded axe
Standard fire axe having a 6 or 8 pound (2.7 to 3.6 kg) steel head with a cutting blade on one edge and a square, pointed pick on the opposite side. Come in various handle lengths.


Pike pole
See Hook.


Platoon
A subdivision of a fire company, led a fire officer of either the rank captain or lieutenant, such that one of several platoons is assigned to duty for a specified period. Also called a watch".


Plec-Tron
Jargon, brand-name of early radio-frequency paging system for summoning firefighters.


Point of origin
An element of fire behavior, indicating where a fire began, supporting further analysis of where the fire went or will go; evidence of specific origin is often obscured or destroyed by suppression tactics.


Pompier ladder:
A style of ladder that is also known as a Scaling Ladder". It is used to climb from one window to another. It differs from other ladders in that it does not rest on the ground it instead uses a large hook at the top to attach to a window sill. The word "Pompier" is French for fireman.


Portable water tank
Collapsible reservoir used for storing water transported to fireground by tanker. May be inflatable or supported by a frame.


Positive pressure
Pressure at higher than atmospheric; used in SCBA facepieces and in smoke-proof stairwells to reduce entry of smoke or fumes through small openings.


Positive Pressure Ventilation (PPV)
Ventilation of an area by the use of a fan to push clean air into that space and controlled use of openings for the escape of smoke and gasses.


Post indicator valve (PIV)
A type of valve used for underground sprinkler shutoff, having a lockable actuator atop a post with a window indicating open" or "shut" status of the valve.


Pre-fire, pre-incident planning
Information collected by fire prevention officers to assist in identifying hazards and the equipment, supplies, personnel, skills, and procedures needed to deal with a potential incident.





Weather


Upcoming Events

Sat. Oct 9th 2010 2:00pm
Squad 18 Housing and Dedication


Every 1st Thu. 7:30pm
Fire Company Meeting


Every 2nd Wed. 7:00pm
Training Night


Every 4th Wed. 7:00pm
Training Night

News Headlines

Wed. Sep 8th 2010
New Company T-Shirts

New t-shirts, sweatshirts and hoodies are in and available for purchase. Please sign up on the order form in the social hall ...

Read more »


Tue. Jul 27th 2010
Squad 18 is here!!

Today we took delivery of our new Squad from E-ONE. Members were on hand as the final paperwork was signed and to go go over ...

Read more »


Sat. Jun 19th 2010
Good news at Dist. 18

First off, Engine 1811 has been sold to a company out of Missouri. 1811 served the township for over 20 years and hopefully w...

Read more »


YourFirstDue.com Managed web hosting for Fire/EMS



Login



Copyright © 2006-2010. YourFirstDue Inc.. All Rights Reserved. Designated trademarks and brands are the property of their respective owners. Content on this web site is supplied by Kidder Twp. Volunteer Fire Company No. 1. YourFirstDue Inc. cannot be held responsible or liable for any content, text, pictures, or any other media found on this web site. Maintained by the members and staff of Kidder Twp. Volunteer Fire Company No. 1.

This site has been
viewed 81,398 times.